Engineered & manufactured in Jewar, India · A part of MT&T Group

Roof & Area Protection

Skylight Protection for Industrial Roofs

Skylights and translucent roof sheets look like part of the roof. However, they rarely take a person's weight. The TsaF skylight mesh system covers roof lights with galvanised mesh panels, so maintenance can continue around them safely while daylight still reaches the floor below.

  • OSHA 1910.29
  • BS EN 1873
Ø3 mm
GI wire mesh
50 × 50 mm
Mesh aperture
625 · 1025 · 1225 mm
Panel widths
TsaF skylight protection mesh fitted over a roof light

The hidden hazard on industrial roofs

Fragile skylights and polycarbonate or fibre roof lights are a serious fall-through hazard. They age and weaken in the sun. They are also often dirty enough to look like solid sheet, and they sit right where workers walk to reach fans, gutters and plant. As a result, a person who steps or stumbles onto one can fall straight through to the floor below. Protecting skylights is therefore one of the most important steps in making a working roof safe.

How the TsaF skylight mesh system works

The TsaF Skylight Mesh System covers each roof light with a panel of high-strength galvanised (GI) wire mesh. For example, it uses Ø3 mm wire at 50 × 50 mm spacing on a mild steel angle frame of 32 × 32 × 3 mm, with supports at 500 mm centres. The mesh securely covers the opening while natural light passes through. Consequently, the building keeps its daylight and the energy savings that come with it.

Panel types and sizes

We offer framed or flat-sheet panels in widths of 625, 1025 and 1225 mm and lengths of 3006 and 2500 mm. In addition, adjustable height suits different roof light shapes and upstands. Hot-dip galvanised components also help the system resist moisture and wear in outdoor conditions.

Fixing without damaging the roof

On standing seam roofs, the panels use a non-penetrating compression clamp, so the roof sheet stays intact. On trapezoidal roofs, however, aluminium rivets and EPDM washers hold the panels, and weatherproof adhesive tapes prevent water leakage.

According to the catalogue, the mesh meets OSHA 1910.29 skylight screen requirements and BS EN 1873, retaining a 50 kg mass dropped from 2.4 m. TsaF engineering will, however, confirm the test data for the panel type and size proposed for your roof.

A complete approach to roof lights

Mesh protects the roof light itself. Around skylights on busy routes, TsaF also often adds a rooftop barricade or modular safety barrier. Similarly, an aluminium walkway keeps people off the sheets, and a horizontal lifeline gives personal protection.

Why TsaF

TsaF has supplied skylight protection since 2010. First, we count and measure every roof light during the survey. Then we manufacture panels to size in Jewar, and our certified technicians install them. After that, the Annual Maintenance Check inspects mesh panels, fixings, frames and seals every year. Request a site assessment to have your skylights checked.

Specifications are indicative. Refer to the product datasheet or ask our engineers for project-specific values.

System types

Configured for your structure

01

Framed mesh panel (TSAF126)

GI mesh on a mild steel angle frame, for roof lights that need a rigid, height-adjustable panel.

02

Flat-sheet mesh panel

Flat GI mesh panel for roof lights that sit close to the roof profile.

03

Standing seam fixing

Non-penetrating compression clamps grip the seam, so the roof sheet stays intact.

04

Trapezoidal roof fixing

Aluminium rivets with EPDM washers and weatherproof adhesive tapes, so water does not leak in.

How it works

Engineered component by component

  1. Survey and measurementFirst, we count and measure every roof light and check its shape, upstand and roof profile.
  2. Mesh panelØ3 mm GI wire mesh at 50 × 50 mm spacing then covers the opening while letting daylight through.
  3. Frame and supportsA 32 × 32 × 3 mm mild steel angle frame with supports at 500 mm centres also carries the mesh.
  4. Height adjustmentAdjustable height lets panels suit different roof light shapes and upstands.
  5. Roof fixingFinally, non-penetrating clamps fix panels on standing seam roofs, while rivets with EPDM washers suit trapezoidal roofs.

Benefits

Why sites choose this system

Fall-through protection

Mesh panels cover fragile roof lights along working routes.

Daylight retained

Open mesh lets natural light through, so you keep illumination and energy efficiency.

Protects the roof

Non-penetrating clamps on standing seam roofs; sealed rivet fixings on trapezoidal roofs.

Weather-resistant

Hot-dip galvanised components resist moisture and wear.

Fits many roof lights

Three widths, two lengths and adjustable height suit different skylight shapes.

Made to size

We manufacture panels in Jewar to the dimensions measured on your roof.

Applications

Where it is used

  • Polycarbonate and fibre roof lights on factory roofs
  • Skylights on warehouse and logistics buildings
  • Ridge ventilators and roof openings along walkways
  • Construction sites with open roof lights
  • Commercial buildings with rooftop skylights

Industries

Hazards this system controls

Standards applicability. This system is designed in accordance withOSHA 1910.29, BS EN 1873. Applicable standards depend on the configuration and components selected — refer to the product datasheet and our engineering documentation for your project.

Installations

On real sites

Keep it fall-arrest ready

Annual Maintenance Check

Documented annual inspection of your skylight protection system by the team that built it.

Explore AMC

FAQs

Questions about theSkylight Protection System

Why are skylights a fall hazard?

Many skylights and translucent roof sheets cannot carry a person's weight, and they also weaken with age and sun exposure. In addition, they can be hard to see when dirty. A worker who steps onto one can therefore fall through to the floor below, so roof lights on working routes need protection.

Will mesh panels block daylight?

No. The TsaF panel uses open GI wire mesh with a 50 × 50 mm aperture, so natural light passes through. As a result, the building keeps its daylight and lighting energy use stays down.

Do the panels need holes drilled in the roof?

On standing seam roofs, TsaF uses a non-penetrating compression clamp that grips the seam, so we never pierce the sheet. On trapezoidal roofs, however, aluminium rivets and EPDM washers hold the panels, with weatherproof tapes against leaks. TsaF confirms the method during the survey.

Which standards is the skylight mesh designed to?

The catalogue references OSHA 1910.29 for skylight screens and BS EN 1873, under which the mesh retains a 50 kg mass dropped from 2.4 m. For your panel type and size, however, refer to the product datasheet.

How are skylight panels maintained?

TsaF recommends an annual inspection. The Annual Maintenance Check covers the mesh panels, fixings, frame and seals, and identifies any corrosion, damage or loosening. In addition, someone should check panels after any roof work or storm damage near the roof lights.

Discuss your site

Get yourskylight protection system engineered

“We don't just install your safety system. We stand on the roof with you.”

Request a callback

Leave your number — an engineer will call you back.

We usually respond within one business day. Prefer to talk? Call +91 99587 88970.